iClaims logo
Internal operations platform

Claim Detail

Search result → immediate full claim view.
Home
Claim explorer / evidence thread
Claim 76718
BARV600 • Ashlee • Paid • keystone
Next Recommended Action

Escalate to State

Payment deadline violated
Reason
OEM Response Deadline Exceeded
Deadline
Payment deadline violated
Estimated recovery
$250.00
risk 0.00 deadline Overdue / escalation ready images 0 matched 0 review 4

Warranty deadline timeline

Track where the claim sits in the recovery workflow, how many days have elapsed, and whether the auto-approval window or payment deadline is already in play.
Uploaded
Completed stage
178d elapsed • 0d remaining
Analyzed
Completed stage
178d elapsed • 0d remaining
Awaiting OEM
Completed stage
178d elapsed • 0d remaining
Auto-Approved
Completed stage
178d elapsed • 0d remaining
Payment Due
Completed stage
178d elapsed • 0d remaining
Escalation Eligible
Completed stage
178d elapsed • 0d remaining
Resolved
Overdue / escalation ready
178d elapsed • 0d remaining • Overdue

AI Claim Analysis

Estimated Recovery Amount
$250.00
What this claim may still be worth based on current evidence.
Compliance Score
100/100
Higher is cleaner. Lower means more missing support, more friction, or more OEM pushback.
Violations Detected
2
OEM Response Deadline Exceeded • Payment Deadline Exceeded
Missing Items
4
No active evidence gaps are listed.
Deadline Status
Overdue / escalation ready
178 days open in the visible workflow.
Recommended Action
Escalate to State
This is the fastest next move from the current workflow stage.

Dossier completeness

Dossier has not been generated yet. Evidence presence is not treated as complete.

US dispute readiness

Evidence packet check

Compact packet candidate
Operational preflight for US warranty escalation: packet size, chronology, cross-references, witness checks, source grounding, and backup evidence.
Estimated pack size
17
Proxy count from docs, images, comments, and claim lines. Actual PDF pages still need final preflight.
Evidence packet lane
Compact packet candidate
Small enough for a compact escalation packet, assuming final PDFs stay clean.
Chronology
Ready to order
Visible span: May 7, 2026, 5:05 AM to Oct 19, 2026, 2:56 AM.
Indexed evidence
3 docs / 24 images
Use only the strongest evidence in the escalation packet; keep the rest as support material.
Cross-reference base
Available
Line items, comments, or gap flags can be tied back to supporting material.
Witness verification
Human verification required
Any statement or affidavit output must be checked by the witness before use.
AI / citation gate
Manual check required
Escalation material must keep facts, inferences, citations, and source documents separated.
Expert evidence pressure
Not signalled
No expert-evidence trigger is visible from the current image rollup.
Escalation posture
Escalation watch
178 days open in the visible workflow; risk score 0.00.

Claim Summary

Evidence summary
No evidence summary yet.
Path
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/76718/WO_76718_2025.05.07_15.04.56.jpg
Timeline
First seen May 7, 2026, 5:05 AM • last seen Oct 19, 2026, 2:56 AM
Evidence flags
No active evidence gap flags

Comment Intelligence

Thread depth
2 indexed side comments on this claim.
Latest visible thread signal
Jun 11, 2025, 3:00 PM • processor • paid $1099.62 6/10 check #1539166
Role mix
Dealer 0 • OEM 0 • Processor 2
Decision cues
Denial signals 0 • info / missing-doc asks 0 • approval signals 0
Best move
Open the focused thread before hunting through the packet manually.

Quick Actions

Back to search results
Run the same search again.
Open focused evidence thread
Jump straight into Dropbox side comments, notes, and support documents.
Open claim explorer
Return to the main recovery queue view.
Open evidence room
See the quick-rule cards first, then open the legal basis only if needed.

Images

Claim Lines

complaint
GFCI OUTLET IN FRONT STORAGE AREA KEEPS TRIPPING FOR TV AND OUTSIDE FRIDGE
needs-review • confidence 0.15
complaint
GFCI OUTLET IN FRONT STORAGE AREA KEEPS TRIPPING FOR TV AND OUTSIDE FRIDGE
needs-review • confidence 0.15
cause
Wall board The Inverter GFCI is shorted after GFCI outlet.
needs-review • confidence 0.21
cause
Wall board The Inverter GFCI is shorted after GFCI outlet.
needs-review • confidence 0.21
correction
Removed corner trim. Peeled back panel. Stapled panel back. Nail corner trim back on. Putty holes. I removed the load side on the back of the GFCI outlet. This allowed the outlet to reset. I checked with a volt meter and found that the other outlets after the GFCI are shorted. The hot wire is making contact with the ground wire. I started at the slide room and living room TV outlets. I started to unhooked one outlet at a time to determine what part of the wiring was shorted. I checked the wiring from the counter top outlet to inside the cabinet. I checked the wiring from the slide room to the underbelly and it was good. I started using a tone generator to track the wiring. I followed the wiring into the wall by the command center to the ceiling. I followed it to the living room TV. I unhooked the wiring there and tested the run from the GFCI to the TV and it tested good. I then followed the wiring from the living room outlet to the outside kitchen refrigerator outlet. I unhooked the outlet and tested that part of the wiring. I found that it was shorted in the roof or back wall before getting to the refrigerator outlet. I followed the next run of wire to inside the underbelly where the slide room plugs in to the wiring. I tested that run of wiring and it texted good. So the only short is in 1 part of the circuit. I can not replace that part of the wiring without removing the back wall and roof. I unhooked the bad run of wiring and I will run a new wire from the back of the GFCI outlet to the slide room outlet wiring. This is the wiring that comes from the refrigerator. So by tying into the run between the 2 outlets with a new power source, I will be able to power the last 2 outlets in the circuit with a new run of wiring and the living room TV will be on the good original circuit. I ran a new For paper claims only only ­use one pre­authorization number per warranty claim form Staple a copy of this pre­authorization to a warranty claim form. Fill out the header information and the
partial-match • confidence 0.42
correction
Removed corner trim. Peeled back panel. Stapled panel back. Nail corner trim back on. Putty holes. I removed the load side on the back of the GFCI outlet. This allowed the outlet to reset. I checked with a volt meter and found that the other outlets after the GFCI are shorted. The hot wire is making contact with the ground wire. I started at the slide room and living room TV outlets. I started to unhooked one outlet at a time to determine what part of the wiring was shorted. I checked the wiring from the counter top outlet to inside the cabinet. I checked the wiring from the slide room to the underbelly and it was good. I started using a tone generator to track the wiring. I followed the wiring into the wall by the command center to the ceiling. I followed it to the living room TV. I unhooked the wiring there and tested the run from the GFCI to the TV and it tested good. I then followed the wiring from the living room outlet to the outside kitchen refrigerator outlet. I unhooked the outlet and tested that part of the wiring. I found that it was shorted in the roof or back wall before getting to the refrigerator outlet. I followed the next run of wire to inside the underbelly where the slide room plugs in to the wiring. I tested that run of wiring and it texted good. So the only short is in 1 part of the circuit. I can not replace that part of the wiring without removing the back wall and roof. I unhooked the bad run of wiring and I will run a new wire from the back of the GFCI outlet to the slide room outlet wiring. This is the wiring that comes from the refrigerator. So by tying into the run between the 2 outlets with a new power source, I will be able to power the last 2 outlets in the circuit with a new run of wiring and the living room TV will be on the good original circuit. I ran a new For paper claims only only ­use one pre­authorization number per warranty claim form Staple a copy of this pre­authorization to a warranty claim form. Fill out the header information and the
partial-match • confidence 0.42

Evidence Thread

Ashlee Olsen
processor • Jun 2, 2025, 4:45 PM
submitted C3816537
Ashlee Olsen
processor • Jun 11, 2025, 3:00 PM
paid $1099.62 6/10 check #1539166

Claim Files

CLAIM.pdf
main-pdf • Jun 2, 2025, 4:38 PM • 804,016 bytes
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/76718/CLAIM.pdf
RO 76718.pdf
pdf • Jun 2, 2025, 4:37 PM • 843,215 bytes
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/76718/RO 76718.pdf
PREAUTH.pdf
main-pdf • Jun 2, 2025, 4:32 PM • 57,308 bytes
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/76718/PREAUTH.pdf