Case Control
Claim Explorer
Find a claim fast, see its current state, and identify what is blocking resolution.
Recovery workflow

Claims, stripped down to action.

Search fast, see the money, understand the stage, and move the next claim without spelunking through garbage labels or filler blocks.
Estimated recovery
$0.00
Live visible unpaid or underpaid dollars.
Short-paid
$0.00
Claims still needing recovery or escalation.
Avg claim age
59
Average days since submission in view.
Payment due runway
0
Average days until OEM payment is due.

Claim Evidence Detail

73090-2
MYRV 12024 • Approved / Unpaid • prime-time
No evidence summary yet.
Path: /home/openclaw/nas/Dropbox/MYRV 12024/5- Pre-Authorizations Approved- MYRV/Prime Time/73090-2/Integrity Management Advisors Mail - RE_ 2798967 - line 4.pdf
risk 0.00 images 0 classified 0 damage 0 docs 0 matched 2 partial 17 review 32
No browser-previewable images were available for this claim yet.
correction
Pulled the switch panel off of the wall tested for power and ground of the awning switch. I had 8 V at the switch and had a good ground. Tested the switch for proper function and it does function properly. Disconnected the switch leg to the awning which is yellow and white. Found the white wire has a short to ground. I pulled on the yellow and white wire that comes through the ceiling and I was able to free up about 6 inches and the short in the white wire went away. My guess it was just a staple and I pulled the staple out. There is no more short Im not going to run a new wire at this time however if this issue comes back I will have to run a new wire from the switch panel down to the awning. As far as the low-voltage goes the black and white wire runs across the bottom of the cabinet in the kitchen so we pulled the two lights tested for good connection to make sure there is no voltage drop through the lights didnt see any bad connections. The fuse panel has proper output voltage. We pulled the fuse panel to see where that wire runs and it runs behind the refrigerator. Had to pull the refrigerator to find out whats back there. I had a *1000* good voltage before the refrigerator and bad voltage behind the refrigerator. After removing the refrigerator we found a section of wire that had been stripped and some wires that had been kinked.So we cut out the defective area and reconnected with butt connectors. Tested for proper voltage at the switch panel voltage was correct. All the lights inside and the awning is working now as it should. Refrigerator it had to be reinstalled two lights had to be reinstalled switch panel I had to be reinstalled connections at the awning had to be remade and resealed. Job completed requesting 3 hrs and 45 mins for repair
matched • confidence 0.91
correction
Style is damaged due to the door over closing and rubbing against the style during transport ,need to order and replace style and add rubber stops to prevent further damage to new style .In order to remove the right side style of the shelves I will need to remove all four shelves and the top and the bottom style to gain better access to remove the actual damaged piece of style.will need to remove all 4 shelves on the right side of the pantry. Removing the shelves will require me to remove the framing support for each shelf by removing the seven screws underneath of each shelf and then removing the staplesFor *1000* the style on the front of each side for shelves. Requesting 30 minutes per shelf. There is four shelves Once the shelves are removed I can then start to remove the side trim that is damaged that needs to be replaced.Will need to remove the multiple screws that are screwed city one by one support on the back of the style and that should remove it from the wall. Requesting 45 minutes to remove the right side damaged style . once all of the shelves in the top bottom and sides style or remove I can then cut a new style cut a new style to size and then install the reinstall the shelves individually one at a time once all of the shelves and the top and the bottom style are reinstalled I can then reinstall the right side damaged facia with a new piece and then staple up and secure in the place accordingly. Requesting 4 1/2 hours for removal Replacement and installation of new style. Style dimensions are 3in x 74 in
matched • confidence 0.71
complaint
Wire short for awning / Awning electrical short
partial-match • confidence 0.61
correction
Need to remove plastic door frame and add shims accordingly to adjust the gap of the pantry door when shut . Will require me to peel away plastic piece glued to wood door frame and then scrape away all old adhesive. Then I can add shims as needed to help adjust the door frame gap and allow proper space for the door to close at the top. Once shims are added we can then re install the plastic door frame and test .requesting 1 hr for repair and install of shims
partial-match • confidence 0.58
correction
Pulled the switch panel off of the wall tested for power and ground of the awning switch. I had 8 V at the switch and had a good ground. Tested the switch for proper function and it does function properly. Disconnected the switch leg to the awning which is yellow and white. Found the white wire has a short to ground. I pulled on the yellow and white wire that comes through the ceiling and I was able to free up about 6 inches and the short in the white wire went away. My guess it was just a staple and I pulled the staple out. There is no more short Im not going to run a new wire at this time however if this issue comes back I will have to run a new wire from the switch panel down to the awning. As far as the low-voltage goes the black and white wire runs across the bottom of the cabinet in the kitchen so we pulled the two lights tested for good connection to make sure there is no voltage drop through the lights didnt see any bad connections. The fuse panel has proper output voltage. We pulled the fuse panel to see where that wire runs and it runs behind the refrigerator. Had to pull the refrigerator to find out whats back there. I had a *1000* good voltage before the refrigerator and bad voltage behind the refrigerator. After removing the refrigerator we found a section of wire that had been stripped and some wires that had been kinked.So we cut out the defective area and reconnected with butt connectors. Tested for proper voltage at the switch panel voltage was correct. All the lights inside and the awning is working now as it should. Refrigerator it had to be reinstalled two lights had to be reinstalled switch panel I had to be reinstalled connections at the awning had to be remade and resealed. Job completed requesting 3 hrs and 45 mins for repair
partial-match • confidence 0.56
cause
On the switch leg to the awning which is yellow and white, the white wire was shorted to ground. The supply power to the awning and lights which is a black wire at 8.3 V at the switch. INC., MYERS "RV" CENTER, Customer #: 1000
partial-match • confidence 0.52
Workflow grid

Claim queue

1 visible claims

73090-2 RED Score 24 / 100

MYRV 12024 • Stephanie • prime-time
Escalation Recommended
Recovery
$0.00
Short-Paid
$0.00
Days
59
Escalation Risk • Auto n/a • Payment 0d
3Cs / time / pictures / docs: mismatch / pending / pending / mismatch
Clear
ClaimDealerRepWorkflowOEMDateDays Since SubmissionStatusCommentsFlagsLatest cueRecovery
73090-2 RED Score 24 / 100
3Cs / time / pictures / docs: mismatch / pending / pending / mismatch
MYRV 12024 Stephanie Approved / Unpaid
RO pending
prime-time Sep 3, 2026 59d
Auto n/a
Escalation Recommended
Escalation Risk
Heat 21
18 comments • 0 follow-ups
Escalation Risk @Rhianna S @Kimberly M - It looks like we have two parts in PRO that are still "pending." Please process or comment asap. #16 & #17
Seen
Paid $0.00 • Recovery $0.00
73090-2 RED Score 24 / 100
MYRV 12024 • Stephanie
Escalation Recommended
3Cs / time / pictures / docs: mismatch / pending / pending / mismatch
OEM: prime-time • Date: Sep 3, 2026 • Age: 59d
Estimated Recovery $0.00 • Paid $0.00 • Short $0.00
Auto-Approval n/a • Payment Due 0d
Unknown blocker Heat 21
Escalation Risk
@Rhianna S @Kimberly M - It looks like we have two parts in PRO that are still "pending." Please process or comment asap. #16 & #17
Filtered claim results are shown below, including recovery metrics, deadlines, and blocker cues.
Cleanup

Unknown-stage backlog

159 stage-unknown claims
These are cleanup debt, not honest workflow status.
149 bad claim IDs
Broken names, packet containers, duplicate folder labels, or RO-prefixed junk.
10 parser misses
Claim ID looked usable, but stage detection still failed.
GRE 8220
52 unknown-stage claims • 51 bad claim IDs • 1 parser misses
TRI 1202
52 unknown-stage claims • 49 bad claim IDs • 3 parser misses
BARV600
30 unknown-stage claims • 30 bad claim IDs • 0 parser misses
MYRV 12024
20 unknown-stage claims • 14 bad claim IDs • 6 parser misses
LIN 1025
5 unknown-stage claims • 5 bad claim IDs • 0 parser misses
preauth-needed
37 unknown-stage claims currently point here.
parts-inquiry
29 unknown-stage claims currently point here.
warranty-checks
21 unknown-stage claims currently point here.
no clear path hint
20 unknown-stage claims currently point here.
ready-to-submit
10 unknown-stage claims currently point here.
Examples

Unknown-stage claims

BARV600 / DOMETIC 26
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Aug 18, 2026, 7:01 AM • BARV600 / Warranty Checks Received / DOMETIC 26 / DMTC DEPOSIT 8 14 26.pdf
BARV600 / RV PRO 285692 7 30 26
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Jul 31, 2026, 9:51 AM • BARV600 / Warranty Checks Received / RV PRO 285692 7 30 26 / RV PRO 285692 7 30 26.pdf
BARV600 / GE APPLNCE
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Jul 22, 2026, 3:22 PM • BARV600 / Warranty Checks Received / GE APPLNCE / GE 012729 7 21 26.pdf
BARV600 / KYSTN checks BARV600
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Jul 2, 2026, 12:58 PM • BARV600 / Warranty Checks Received / KYSTN checks BARV600 / KYSTN 1598294 6 25 26.pdf
BARV600 / Claims to be Corrected by Dealer
unknown • Bad claim ID • path suggests info-needed
Last seen: Mar 26, 2026, 12:16 PM • Dropbox / BARV600 / Claims to be Corrected by Dealer / WO_79168_JOB_WINTER_2026.03.11_14.48.19_1.jpeg
BARV600 / 78646 DONT TAKE THIS ONE YET
unknown • Bad claim ID • path suggests claims-to-process
Last seen: Dec 15, 2025, 1:18 PM • BARV600 / Claims to Process-AY / 78646 DONT TAKE THIS ONE YET / CLAIM.pdf
BARV600 / ALNC Checks BARV600
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Oct 21, 2025, 9:45 AM • BARV600 / Warranty Checks Received / ALNC Checks BARV600 / ALNC 128400 10 13 25.pdf
BARV600 / Warranty Checks Received
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Sep 15, 2025, 9:45 PM • Dropbox / BARV600 / Warranty Checks Received / FRVR 3025159 9 11 25.pdf
BARV600 / 76412 - 76148
unknown • Bad claim ID • path suggests claims-to-process
Last seen: Apr 29, 2025, 2:10 PM • BARV600 / Claims to Process-AY / 76412 - 76148 / CLAIM.pdf
BARV600 / RO 76365
unknown • Bad claim ID • path suggests claims-to-process
Last seen: Apr 17, 2025, 11:44 AM • BARV600 / Claims to Process-AY / RO 76365 / CLAIM.pdf
BARV600 / FRVR Checks BARV600
unknown • Bad claim ID • path suggests warranty-checks
Last seen: Jan 27, 2025, 12:31 PM • BARV600 / Warranty Checks Received / FRVR Checks BARV600 / DORMAN.pdf
BARV600 / 74757 updated
unknown • Bad claim ID • path suggests claims-submitted
Last seen: Oct 16, 2024, 12:34 PM • KY sub BA-AO / 74757 / 74757 updated / CLAIM.pdf
BARV600 / 73278 (1)
unknown • Bad claim ID • path suggests claims-submitted
Last seen: Apr 19, 2024, 2:40 PM • Claims Submitted AO / FR sub BA-AO / 73278 (1) / CLAIM.pdf
BARV600 / 72342 . 72348
unknown • Bad claim ID • path suggests claims-submitted
Last seen: Dec 1, 2023, 5:06 PM • Claims Submitted AO / FR sub BA-AO / 72342 . 72348 / CLAIM.pdf
BARV600 / RO 70729
unknown • Bad claim ID • path suggests claims-submitted
Last seen: Jun 14, 2023, 1:04 PM • Claims Submitted AO / KY sub BA-AO / RO 70729 / CLAIM.pdf
BARV600 / 67798 - 68146
unknown • Bad claim ID • path suggests claims-submitted
Last seen: Oct 13, 2022, 3:55 PM • Claims Submitted AO / KY sub BA-AO / 67798 - 68146 / CLAIM.pdf
BARV600 / Claims to Process-AY
unknown • Bad claim ID • path suggests claims-to-process
Last seen: Aug 3, 2022, 2:29 PM • Dropbox / BARV600 / Claims to Process-AY / CLAIM.pdf
BARV600 / 66677 (1)
unknown • Bad claim ID • path suggests claims-to-process
Last seen: Apr 18, 2022, 1:02 PM • BARV600 / Claims to Process-AY / 66677 (1) / CLAIM.pdf