Claim explorer / evidence thread
Claim 77190
BARV600 • Ashlee • Paid • keystone
risk 0.00
deadline Overdue / escalation ready
images 0
matched 1
review 15
Warranty deadline timeline
Track where the claim sits in the recovery workflow, how many days have elapsed, and whether the auto-approval window or payment deadline is already in play.
Uploaded
Completed stage
178d elapsed • 0d remaining
Analyzed
Completed stage
178d elapsed • 0d remaining
Awaiting OEM
Completed stage
178d elapsed • 0d remaining
Auto-Approved
Completed stage
178d elapsed • 0d remaining
Payment Due
Completed stage
178d elapsed • 0d remaining
Escalation Eligible
Completed stage
178d elapsed • 0d remaining
Resolved
Overdue / escalation ready
178d elapsed • 0d remaining • Overdue
AI Claim Analysis
Estimated Recovery Amount
$250.00
What this claim may still be worth based on current evidence.
Compliance Score
100/100
Higher is cleaner. Lower means more missing support, more friction, or more OEM pushback.
Violations Detected
2
OEM Response Deadline Exceeded • Payment Deadline Exceeded
Missing Items
15
No active evidence gaps are listed.
Deadline Status
Overdue / escalation ready
178 days open in the visible workflow.
Recommended Action
Escalate to State
This is the fastest next move from the current workflow stage.
Dossier completeness
Dossier has not been generated yet. Evidence presence is not treated as complete.
US dispute readiness
Evidence packet check
Operational preflight for US warranty escalation: packet size, chronology, cross-references, witness checks, source grounding, and backup evidence.
Estimated pack size
19
Proxy count from docs, images, comments, and claim lines. Actual PDF pages still need final preflight.
Evidence packet lane
Compact packet candidate
Small enough for a compact escalation packet, assuming final PDFs stay clean.
Chronology
Ready to order
Visible span: May 7, 2026, 5:05 AM to Oct 19, 2026, 2:56 AM.
Indexed evidence
3 docs / 24 images
Use only the strongest evidence in the escalation packet; keep the rest as support material.
Cross-reference base
Available
Line items, comments, or gap flags can be tied back to supporting material.
Witness verification
Human verification required
Any statement or affidavit output must be checked by the witness before use.
AI / citation gate
Manual check required
Escalation material must keep facts, inferences, citations, and source documents separated.
Expert evidence pressure
Not signalled
No expert-evidence trigger is visible from the current image rollup.
Escalation posture
Escalation watch
178 days open in the visible workflow; risk score 0.00.
Claim Summary
Evidence summary
No evidence summary yet.
Path
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/77190/WO_77190_JOB_2_2025.07.02_16.29.52.jpg
Timeline
First seen May 7, 2026, 5:05 AM • last seen Oct 19, 2026, 2:56 AM
Evidence flags
No active evidence gap flags
Comment Intelligence
Thread depth
2 indexed side comments on this claim.
Latest visible thread signal
Jul 31, 2025, 1:52 PM • processor • paid $500.79 7/30 check #1547887
Role mix
Dealer 0 • OEM 0 • Processor 2
Decision cues
Denial signals 0 • info / missing-doc asks 0 • approval signals 0
Best move
Open the focused thread before hunting through the packet manually.
Quick Actions
Back to search results
Run the same search again.
Open focused evidence thread
Jump straight into Dropbox side comments, notes, and support documents.
Open claim explorer
Return to the main recovery queue view.
Open evidence room
See the quick-rule cards first, then open the legal basis only if needed.
Images
document-photo
Close-up shows extensive cracking/crazing across a white interior wall or ceiling panel.
Human interpretation • confidence 0.91
document-photo
Dark liquid puddle beneath RV exterior, consistent with an active fluid leak.
Human interpretation • confidence 0.91
document-photo
Low-angle exterior view of RV underside with black trim and a visible wheel.
Human interpretation • confidence 0.72
document-photo
Interior access opening shows bundled wiring and flexible ducting; no clear damage visible.
Human interpretation • confidence 0.64
document-photo
Lower exterior panel seam appears separated with exposed edge material.
Human interpretation • confidence 0.77
document-photo
Close-up of cabinet plumbing with black fittings and white water lines; no clear damage visible.
Human interpretation • confidence 0.68
document-photo
Water visibly leaks from two points along the RV underbody seam.
Human interpretation • confidence 0.94
document-photo
Close-up of plumbing valve and water lines inside cabinet; no clear damage visible.
Human interpretation • confidence 0.78
document-photo
Close-up of wiring and a black textured flexible duct/material; no clear damage visible.
Human interpretation • confidence 0.58
document-photo
Interior compartment shows exposed wiring, ducting, and a metal support rod; no clear damage visible.
Human interpretation • confidence 0.58
document-photo
Close-up of a black hose with brass fitting connected beneath an exterior panel.
Human interpretation • confidence 0.72
document-photo
Ground-level view of a black RV underbody tank or enclosure; no clear damage visible.
Human interpretation • confidence 0.72
document-photo
Close-up of an RV exterior fitting with a connected black hose and brass coupler.
Human interpretation • confidence 0.84
document-photo
Close-up of wiring harness routed through a black panel opening; no clear damage visible.
Human interpretation • confidence 0.82
document-photo
Underside plumbing and hanging trim panel shown; no clear break or leak visible.
Human interpretation • confidence 0.78
document-photo
Damaged or displaced black underbody panel exposes wiring and a white tube.
Human interpretation • confidence 0.82
document-photo
Exposed wiring and connector visible beneath a black panel.
Human interpretation • confidence 0.82
document-photo
Interior access area shows exposed wiring and a displaced white trim/panel piece.
Human interpretation • confidence 0.81
document-photo
Undercarriage view showing black electrical/battery components and wiring; no clear damage visible.
Human interpretation • confidence 0.65
document-photo
Underside view shows a bent and partially detached diamond-plate skirt/panel near the axle.
Human interpretation • confidence 0.88
document-photo
Close-up of a rough opening in black underbelly material exposing hoses and wiring.
Human interpretation • confidence 0.93
document-photo
Under-sink view showing black drain trap and connected plumbing.
Human interpretation • confidence 0.84
document-photo
Black trim/bracket is cracked and separated beside a white molded panel.
Human interpretation • confidence 0.86
document-photo
Underside view shows exposed wiring and a torn or cut black underbody panel.
Human interpretation • confidence 0.68
Claim Lines
complaint
UNDER BELLY IS FULL OF WATER
needs-review • confidence 0.28
complaint
UNDER BELLY IS FULL OF WATER
needs-review • confidence 0.15
cause
Water line to the black tank flush had a kink that it was leaking at the kink and leaking into to the underbelly.
needs-review • confidence 0.34
cause
Water line to the black tank flush had a kink that it was leaking at the kink and leaking into to the underbelly.
needs-review • confidence 0.21
correction
When pulling the camper from the sales lot had noticed front underbelly was leaking water. Set the camper outside of the service bay. Lower the front of the camper and unscrewed some of the self tappers to drain out the water. Connected the garden hose to the winterizing port and checked for leaks. Disconnected the hose and connected to the city water connection and checked for leaks. Disconnected the hose and connected to the black tank flush connection. Turned on the water but didn't hear it flowing. Went inside the camper and checked the black tank flush and it was quiet. Got a job to fix the backwards vacuum breaker. After checking those connections never found a leak yet. After looking into the underbelly found the water line to the black tank flush was leaking at the kink. Cut the underbelly to get closer to the kinked water line. Cut out the kink in the water line and got a elbow fitting from the
partial-match • confidence 0.55
correction
When pulling the camper from the sales lot had noticed front underbelly was leaking water. Set the camper outside of the service bay. Lower the front of the camper and unscrewed some of the self tappers to drain out the water. Connected the garden hose to the winterizing port and checked for leaks. Disconnected the hose and connected to the city water connection and checked for leaks. Disconnected the hose and connected to the black tank flush connection. Turned on the water but didn't hear it flowing. Went inside the camper and checked the black tank flush and it was quiet. Got a job to fix the backwards vacuum breaker. After checking those connections never found a leak yet. After looking into the underbelly found the water line to the black tank flush was leaking at the kink. Cut the underbelly to get closer to the kinked water line. Cut out the kink in the water line and got a elbow fitting from the
partial-match • confidence 0.43
complaint
VACUM BREAKER IS BACKWARDS
needs-review • confidence 0.32
complaint
VACUM BREAKER IS BACKWARDS
needs-review • confidence 0.00
cause
Vacuum breaker
needs-review • confidence 0.32
cause
Vacuum breaker
needs-review • confidence 0.00
correction
When the hose, is connected to the black tank,could not hear the water flow, and the black tank was dry. Went to the vacuum breaker and couldn't hear any water flowing. Disconnected the vacuum breaker. Switched the fittings, that didn't help fix the issue. The vacuum breaker was bad because of being backwards, got a new vacuum breaker from the
matched • confidence 0.66
correction
When the hose, is connected to the black tank,could not hear the water flow, and the black tank was dry. Went to the vacuum breaker and couldn't hear any water flowing. Disconnected the vacuum breaker. Switched the fittings, that didn't help fix the issue. The vacuum breaker was bad because of being backwards, got a new vacuum breaker from the
needs-review • confidence 0.22
complaint
AREA NEAR THE BACK SPLASH IS TORN AND NEEDS TO BE FIXED
needs-review • confidence 0.31
complaint
AREA NEAR THE BACK SPLASH IS TORN AND NEEDS TO BE FIXED
needs-review • confidence 0.13
cause
FOUND AREA DAMAGED
needs-review • confidence 0.31
cause
FOUND AREA DAMAGED
needs-review • confidence 0.18
correction
INSTALL SEAM TAPE OVER AREA PreAuthorization number: PA03884674 2.50 For paper claims only only use one preauthorization number per warranty claim form Staple a copy of this preauthorization to a warranty claim form. Fill out the header information and the
needs-review • confidence 0.31
correction
INSTALL SEAM TAPE OVER AREA PreAuthorization number: PA03884674 2.50 For paper claims only only use one preauthorization number per warranty claim form Staple a copy of this preauthorization to a warranty claim form. Fill out the header information and the
needs-review • confidence 0.13
Evidence Thread
Ashlee Olsen
processor • Jul 18, 2025, 12:09 PM
submitted C3836255
Ashlee Olsen
processor • Jul 31, 2025, 1:52 PM
paid $500.79 7/30 check #1547887
Claim Files
CLAIM.pdf
main-pdf • Jul 18, 2025, 11:35 AM • 782,336 bytes
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/77190/CLAIM.pdf
RO 77190.pdf
pdf • Jul 18, 2025, 11:35 AM • 974,336 bytes
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/77190/RO 77190.pdf
PREAUTH.pdf
main-pdf • Jul 18, 2025, 11:15 AM • 57,664 bytes
/home/openclaw/nas/Dropbox/BARV600/Claims Paid AO/77190/PREAUTH.pdf