Claim explorer / evidence thread
Claim 72414-4
MYRV 12024 • Stephanie • Paid • open-range
risk 0.00
deadline Overdue / escalation ready
images 0
matched 1
review 2
Warranty deadline timeline
Track where the claim sits in the recovery workflow, how many days have elapsed, and whether the auto-approval window or payment deadline is already in play.
Uploaded
Completed stage
68d elapsed • 0d remaining
Analyzed
Completed stage
68d elapsed • 0d remaining
Awaiting OEM
Completed stage
68d elapsed • 0d remaining
Auto-Approved
Completed stage
68d elapsed • 0d remaining
Payment Due
Completed stage
68d elapsed • 0d remaining
Escalation Eligible
Completed stage
68d elapsed • 0d remaining
Resolved
Overdue / escalation ready
68d elapsed • 0d remaining • Overdue
AI Claim Analysis
Estimated Recovery Amount
Pending payment match
What this claim may still be worth based on current evidence.
Compliance Score
100/100
Higher is cleaner. Lower means more missing support, more friction, or more OEM pushback.
Violations Detected
2
OEM Response Deadline Exceeded • Payment Deadline Exceeded
Missing Items
2
No active evidence gaps are listed.
Deadline Status
Overdue / escalation ready
68 days open in the visible workflow.
Recommended Action
Escalate to State
This is the fastest next move from the current workflow stage.
US dispute readiness
Evidence packet check
Operational preflight for US warranty escalation: packet size, chronology, cross-references, witness checks, source grounding, and backup evidence.
Estimated pack size
4
Proxy count from docs, images, comments, and claim lines. Actual PDF pages still need final preflight.
Evidence packet lane
Compact packet candidate
Small enough for a compact escalation packet, assuming final PDFs stay clean.
Chronology
Ready to order
Visible span: Jun 25, 2026, 10:58 AM to Jul 27, 2026, 2:54 AM.
Indexed evidence
2 docs / 0 images
Use only the strongest evidence in the escalation packet; keep the rest as support material.
Cross-reference base
Available
Line items, comments, or gap flags can be tied back to supporting material.
Witness verification
Human verification required
Any statement or affidavit output must be checked by the witness before use.
AI / citation gate
Manual check required
Escalation material must keep facts, inferences, citations, and source documents separated.
Expert evidence pressure
Not signalled
No expert-evidence trigger is visible from the current image rollup.
Escalation posture
Escalation watch
68 days open in the visible workflow; risk score 0.00.
Claim Summary
Evidence summary
No evidence summary yet.
Path
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/July 2026/Open Range/72414-4/Paid claim.pdf
Timeline
First seen Jun 25, 2026, 10:58 AM • last seen Jul 27, 2026, 2:54 AM
Evidence flags
No active evidence gap flags
Comment Intelligence
Thread depth
3 indexed side comments on this claim.
Latest visible thread signal
Jul 9, 2026, 12:18 PM • processor • Paid $269.33 check 477521 7/6/2026
Role mix
Dealer 0 • OEM 0 • Processor 3
Decision cues
Denial signals 0 • info / missing-doc asks 0 • approval signals 1
Best move
Thread shows approval language — verify payment / closeout.
Quick Actions
Back to search results
Run the same search again.
Open focused evidence thread
Jump straight into Dropbox side comments, notes, and support documents.
Open claim explorer
Return to the main recovery queue view.
Open evidence room
See the quick-rule cards first, then open the legal basis only if needed.
Images
No browser-previewable images were available for this claim yet.
Claim Lines
complaint
FUSE BLOWS FOR LIGHT CIRCUIT
needs-review • confidence 0.30
cause
Blowing fuses INC., MYERS "RV" CENTER, Customer #: 1000
needs-review • confidence 0.27
correction
Found on a separate job (work order #72414-2)of repairing the wall and having to take down cabinets prior to putting in the cabinets back up, tested the lights above the kitchen sink found it had no power. Checked the fuse panel found a burnt fuse and it was designated for the kitchen sink light monitor panel and water pump. Attempted to put a new fuse in and it immediately burnt the new fuse. Disconnected the light and attempted to put in another fuse and burnt the fuse again. Disconnected the water pump and attempted another fuse and it burned that fuse. Reset fuse link, plugged it into the socket, removed the control panel for the monitor panel and the access panel to the wiring on the backside disconnected the monitor panel. Attempted to use the resettable fuse and immediately bles the fuse. Took the cover off with the electric panel looked at the wires for that fuse bar found that there were three wires, two green and an orange disconnected. All three wired plug the resettable fuse back in and one wire at a time tested to see which one tripped the fuse. The orange wire was tripping the fuse. The green wires were *1000* not tripping the fuse. Connected the green wires back to the bar. The orange wire disconnected. Reconnected the light above the kitchen sink, fuse did not blow. Light worked. Reconnected the water pump, water pump worked did not blow the fuse. Reconnected the monitor panel. Check the monitor panel for functionality. The monitor panel was working on all aspects battery, freshwater, blackwater water giving correct readings. All components according to the face in the markings for the fuse bar now working. Began testing all 12 V systems in the unit to attempt to find what the orange wire was meant for. Tested all USB ports turned on every light in the unit. checked the compartment light. Lights tested the furnace verified. The water heater was working and the radio, cable TV booster all components were working and working correctly check the propane CO2. It was also operational could not find any component on the entire unit that this wire would be controlling with every 12 V working. Verified that the range hood was working, the fan was working. The light was working power to the stove and oven were both working, which is 12 V also ran the awning out checked the awning lights. Everything was working. Removed the entire electric panel out of the hole to trace the orange wire. Traceed the wire went straight up behind the pantry cabinet towards the ceiling. As far as I could reach could not find a junction box it sounded like the entire wire band went into the ceiling of the unit. Space is not large enough to look into to see exactly where the orange wire goes. Checked the garnish from the ceiling vent in the bathroom to check and see if it was pre-wire for a fan vent since this vent is not powered or has a fan built-in. Did not find any wiring related to the orange wire in the ceiling. Unable to locate the specific circuit that the orange wire goes to. The wire was removed from the electric panel. It was capped off behind the electric panel. The electric panel was reinstalled. Screwed back into place cover put back on. The monitor panel was put back into place, reinstalled, screwed back to the side of the cabinet. Verified that everything was completely connected plugged in properly reinstalled the access panel. This work is now complete. Requesting 1.5hr Page 1 of 2 © 2026 Integrated Dealer Systems *72414-4* Promised Date: 30 JUN 26 W/O: 72414-4
matched • confidence 0.87
Evidence Thread
Stephanie Kendziorski
processor • Jun 25, 2026, 10:58 AM
@Jeannette B Approved 1.5 hours
Stephanie Kendziorski
processor • Jun 30, 2026, 10:59 AM
Submitted for payment
Stephanie Kendziorski
processor • Jul 9, 2026, 12:18 PM
Paid $269.33 check 477521 7/6/2026
Claim Files
72414-4F.pdf
main-pdf • Jun 30, 2026, 10:26 AM • 311,705 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/July 2026/Open Range/72414-4/72414-4F.pdf
72414-4.pdf
main-pdf • Jun 24, 2026, 3:46 PM • 310,411 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/July 2026/Open Range/72414-4/72414-4.pdf