Claim explorer / evidence thread
Claim 73601
MYRV 12024 • Stephanie • Paid • open-range
risk 0.00
deadline Overdue / escalation ready
images 0
matched 0
review 7
Warranty deadline timeline
Track where the claim sits in the recovery workflow, how many days have elapsed, and whether the auto-approval window or payment deadline is already in play.
Uploaded
Completed stage
53d elapsed • 0d remaining
Analyzed
Completed stage
53d elapsed • 0d remaining
Awaiting OEM
Completed stage
53d elapsed • 0d remaining
Auto-Approved
Completed stage
53d elapsed • 0d remaining
Payment Due
Completed stage
53d elapsed • 0d remaining
Escalation Eligible
Completed stage
53d elapsed • 0d remaining
Resolved
Overdue / escalation ready
53d elapsed • 0d remaining • Overdue
AI Claim Analysis
Estimated Recovery Amount
$250.00
What this claim may still be worth based on current evidence.
Compliance Score
100/100
Higher is cleaner. Lower means more missing support, more friction, or more OEM pushback.
Violations Detected
2
OEM Response Deadline Exceeded • Payment Deadline Exceeded
Missing Items
7
No active evidence gaps are listed.
Deadline Status
Overdue / escalation ready
53 days open in the visible workflow.
Recommended Action
Escalate to State
This is the fastest next move from the current workflow stage.
US dispute readiness
Evidence packet check
Operational preflight for US warranty escalation: packet size, chronology, cross-references, witness checks, source grounding, and backup evidence.
Estimated pack size
5
Proxy count from docs, images, comments, and claim lines. Actual PDF pages still need final preflight.
Evidence packet lane
Compact packet candidate
Small enough for a compact escalation packet, assuming final PDFs stay clean.
Chronology
Ready to order
Visible span: Jul 10, 2026, 10:10 AM to Aug 1, 2026, 2:55 AM.
Indexed evidence
2 docs / 0 images
Use only the strongest evidence in the escalation packet; keep the rest as support material.
Cross-reference base
Available
Line items, comments, or gap flags can be tied back to supporting material.
Witness verification
Human verification required
Any statement or affidavit output must be checked by the witness before use.
AI / citation gate
Manual check required
Escalation material must keep facts, inferences, citations, and source documents separated.
Expert evidence pressure
Not signalled
No expert-evidence trigger is visible from the current image rollup.
Escalation posture
Monitor
53 days open in the visible workflow; risk score 0.00.
Claim Summary
Evidence summary
No evidence summary yet.
Path
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/July 2026/Open Range/73601/Paid claim.pdf
Timeline
First seen Jul 10, 2026, 10:10 AM • last seen Aug 1, 2026, 2:55 AM
Evidence flags
No active evidence gap flags
Comment Intelligence
Thread depth
4 indexed side comments on this claim.
Latest visible thread signal
Jul 28, 2026, 1:30 PM • processor • Paid $247.47 check 480655 7/20/2026
Role mix
Dealer 0 • OEM 0 • Processor 4
Decision cues
Denial signals 0 • info / missing-doc asks 0 • approval signals 2
Best move
Thread shows approval language — verify payment / closeout.
Quick Actions
Back to search results
Run the same search again.
Open focused evidence thread
Jump straight into Dropbox side comments, notes, and support documents.
Open claim explorer
Return to the main recovery queue view.
Open evidence room
See the quick-rule cards first, then open the legal basis only if needed.
Images
No browser-previewable images were available for this claim yet.
Claim Lines
complaint
CUSTOMER STATES THE AC IS NOT KICKING ON AFTER 4 TO 5HRS. CLICK AND THEN HUM FOR A FEW MINUTES BEFORE KICKING ON. CUSTOMER IS OPERATING IN THE AUTO MODE.
needs-review • confidence 0.30
cause
Ac is turning off after 4-5 hrs run time and will not start back up makes a click then hum sound
needs-review • confidence 0.30
correction
Noticed some air leaking into return from cold air supply ,and used foil tape to properly seal return of ac to help get accurate readings.Armando at airxcel had me test for power between the board and compressor and had good 116v power.freeze sensor tested good .when the unit starts to get to temp is when it starts to kick on and off the compressor which is normal. When compressor runs up to ten seconds *54660* before fan kicks on is normal . Was not able to replicate customer complaint , every time it turns on shortly after being turned on .
partial-match • confidence 0.47
complaint
CUSTOMER STATES AC IS NOT COOLING PROPERLY
needs-review • confidence 0.28
cause
ADB NOT SEALED PROPERLY BETWEEN INPUT/OUTPIT
needs-review • confidence 0.28
correction
RETAPED AND RESEALED INPUT/OUTPUT .50HRS
needs-review • confidence 0.28
complaint
CUSTOMER STATES ENTRY DOOR WILL NOT CLOSE WHEN THE DOOR IS HOT FROM THE HEAT OF THE SUN
needs-review • confidence 0.27
cause
MISALIGNED
needs-review • confidence 0.04
correction
adjust door frame slightly to allow more space for door to latch properly . Will need to remove screws in outside edge of door to allow frame to adjust . Once door frame is adjusted will need to flatten lower part of the strike plate to allow for smoother closing of the door and tighten up screw gaps Requesting .85HS
partial-match • confidence 0.41
Evidence Thread
Stephanie Kendziorski
processor • Jul 10, 2026, 10:10 AM
Submitted PA J01587523
Stephanie Kendziorski
processor • Jul 13, 2026, 11:21 AM
@Brian P Job 1A- approved .5
Job 2 approved .85
Stephanie Kendziorski
processor • Jul 15, 2026, 1:44 PM
Submitted for payment
Stephanie Kendziorski
processor • Jul 28, 2026, 1:30 PM
Paid $247.47 check 480655 7/20/2026
Claim Files
73601F.pdf
main-pdf • Jul 14, 2026, 6:21 PM • 314,153 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/7- Claims in Process/7.1- Claims Submitted- iCS/Open Range/73601/73601F.pdf
73601.pdf
main-pdf • Jul 9, 2026, 4:37 PM • 312,674 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/7- Claims in Process/7.1- Claims Submitted- iCS/Open Range/73601/73601.pdf