Claim explorer / evidence thread
Claim 72859
MYRV 12024 • Stephanie • Paid • prime-time
risk 0.00
deadline Overdue / escalation ready
images 0
matched 1
review 16
Warranty deadline timeline
Track where the claim sits in the recovery workflow, how many days have elapsed, and whether the auto-approval window or payment deadline is already in play.
Uploaded
Completed stage
178d elapsed • 0d remaining
Analyzed
Completed stage
178d elapsed • 0d remaining
Awaiting OEM
Completed stage
178d elapsed • 0d remaining
Auto-Approved
Completed stage
178d elapsed • 0d remaining
Payment Due
Completed stage
178d elapsed • 0d remaining
Escalation Eligible
Completed stage
178d elapsed • 0d remaining
Resolved
Overdue / escalation ready
178d elapsed • 0d remaining • Overdue
AI Claim Analysis
Estimated Recovery Amount
$125.00
What this claim may still be worth based on current evidence.
Compliance Score
100/100
Higher is cleaner. Lower means more missing support, more friction, or more OEM pushback.
Violations Detected
2
OEM Response Deadline Exceeded • Payment Deadline Exceeded
Missing Items
16
No active evidence gaps are listed.
Deadline Status
Overdue / escalation ready
178 days open in the visible workflow.
Recommended Action
Escalate to State
This is the fastest next move from the current workflow stage.
Dossier completeness
Dossier has not been generated yet. Evidence presence is not treated as complete.
US dispute readiness
Evidence packet check
Operational preflight for US warranty escalation: packet size, chronology, cross-references, witness checks, source grounding, and backup evidence.
Estimated pack size
20
Proxy count from docs, images, comments, and claim lines. Actual PDF pages still need final preflight.
Evidence packet lane
Compact packet candidate
Small enough for a compact escalation packet, assuming final PDFs stay clean.
Chronology
Ready to order
Visible span: May 7, 2026, 5:36 AM to Jun 25, 2026, 2:54 AM.
Indexed evidence
4 docs / 22 images
Use only the strongest evidence in the escalation packet; keep the rest as support material.
Cross-reference base
Available
Line items, comments, or gap flags can be tied back to supporting material.
Witness verification
Human verification required
Any statement or affidavit output must be checked by the witness before use.
AI / citation gate
Manual check required
Escalation material must keep facts, inferences, citations, and source documents separated.
Expert evidence pressure
Not signalled
No expert-evidence trigger is visible from the current image rollup.
Escalation posture
Escalation watch
178 days open in the visible workflow; risk score 0.00.
Claim Summary
Evidence summary
No evidence summary yet.
Path
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/April 2026/Primetime/72859/Paid claim.pdf
Timeline
First seen May 7, 2026, 5:36 AM • last seen Jun 25, 2026, 2:54 AM
Evidence flags
No active evidence gap flags
Comment Intelligence
Thread depth
5 indexed side comments on this claim.
Latest visible thread signal
Apr 8, 2026, 10:11 AM • processor • Paid $1049.75 check 3136259 4/7/2026
Role mix
Dealer 0 • OEM 0 • Processor 4
Decision cues
Denial signals 0 • info / missing-doc asks 3 • approval signals 3
Best move
Work missing-doc or reply asks first from the thread.
Quick Actions
Back to search results
Run the same search again.
Open focused evidence thread
Jump straight into Dropbox side comments, notes, and support documents.
Open claim explorer
Return to the main recovery queue view.
Open evidence room
See the quick-rule cards first, then open the legal basis only if needed.
Images
document-photo
GE appliance data plate for an indoor air-conditioner assembly; no damage visible.
Human interpretation • confidence 0.93
document-photo
RV interior with an opened electrical control enclosure and exposed wiring during service.
Human interpretation • confidence 0.82
document-photo
Open RV electrical distribution/control panel with wiring, fuses, breakers, and active indicator light.
Human interpretation • confidence 0.84
document-photo
Photo shows underside of an installed gas cooktop with wiring, gas line, and appliance labels.
Human interpretation • confidence 0.58
document-photo
Exposed multicolored wiring and disconnected switch/connector beside window blind.
Human interpretation • confidence 0.84
document-photo
Photo shows loose, unterminated wiring beside a water pump and plumbing hoses.
Human interpretation • confidence 0.86
document-photo
Detached Time Time RV slide/awning control panel with exposed wiring.
Human interpretation • confidence 0.84
document-photo
Close-up confirms an Aqua-Flo water-system pump; no visible damage or leak.
Human interpretation • confidence 0.90
document-photo
Photo shows insulated ducting and wiring behind an appliance panel; no clear damage visible.
Human interpretation • confidence 0.58
document-photo
Foil tape is visibly applied around black ducting near a labeled appliance compartment.
Human interpretation • confidence 0.72
document-photo
Close-up of Aqua-Flo water system pump; no visible damage or claim-specific identifier.
Human interpretation • confidence 0.90
document-photo
Exposed, disconnected wiring and a hanging control/display module inside an RV wall.
Human interpretation • confidence 0.86
document-photo
Interior appliance view showing GE-labeled component, braided hoses, wiring, and foil-wrapped assembly.
Human interpretation • confidence 0.52
document-photo
Interior view shows a black corrugated duct and wiring above a Furrion display; no clear damage visible.
Human interpretation • confidence 0.52
document-photo
GE appliance data plate and QR label shown; no damage visible.
Human interpretation • confidence 0.72
document-photo
Exposed, disconnected electrical wiring and loose connectors are visible beside a shower enclosure.
Human interpretation • confidence 0.88
document-photo
Flashlight inspection of an underbody cavity; no clear damage or unit identity is visible.
Human interpretation • confidence 0.42
document-photo
Photo shows a GE-labeled electrical component with wiring and insulated ducting; no clear damage visible.
Human interpretation • confidence 0.43
document-photo
Dark, unclear view of an underside panel or trim; no defect can be confirmed.
Human interpretation • confidence 0.13
document-photo
GE air-conditioner data label identifies model GRHS15XAHWH1 and serial GAQ46844Z.
Human interpretation • confidence 0.92
document-photo
Dark interior photo shows a loose white panel or trim piece; damage and location unclear.
Human interpretation • confidence 0.32
document-photo
Dark photo of an air-conditioner electrical/refrigerant label; no damage is visible.
Human interpretation • confidence 0.62
Claim Lines
complaint
WARRANTY ITEM
needs-review • confidence 0.00
cause
Water pump kills battery power when running. Water pump only works when living room light switch is on. All lights dim severely when pump is running and power drops from 13.5 to 10.3 volts. Converter, battery and 120 in are all passing inspection.
partial-match • confidence 0.53
correction
After extensive diagnostics, found no dedicated circuit for monitor panel or water pump. Ground supply was bad to bathroom wiring as well. Ran test circuits to verify problem and confirm resolution. Need to run a dedicated circuit from panel in living room to water pump controls in bathroom. Must run new ground from 12 volt distribution panel to bathroom to resolve bad ground issue. Must remove *1000* water pump from living room light circuit. Repaired wiring and tested
matched • confidence 0.81
complaint
WARRANTY ITEM
needs-review • confidence 0.00
cause
Monitor panel in bathroom only has power when living room light switch is on.
needs-review • confidence 0.27
correction
REFERNENCE JOB 1
needs-review • confidence 0.00
complaint
WARRANTY ITEM Page 1 of 3 © 2026 Integrated Dealer Systems *72859* Promised Date: 03 APR 26 W/O: 72859
needs-review • confidence 0.00
cause
Air conditioner in living room quick cycling compressor
needs-review • confidence 0.11
correction
Sealed plenum and tested. Completed
needs-review • confidence 0.00
complaint
WARRANTY ITEM
needs-review • confidence 0.00
cause
Bedroom door peeling *72859*
needs-review • confidence 0.00
correction
NOTE
needs-review • confidence 0.00
complaint
WARRANTY ITEM
needs-review • confidence 0.00
cause
Scratches on cabinet in bedroom
needs-review • confidence 0.00
correction
NOTE
needs-review • confidence 0.00
complaint
Transferred to RV*72859-1 on 27 MAR 26 Estimate amount was 0.00 PRE-PDI NEW TT - 3.0
needs-review • confidence 0.00
cause
Pre
needs-review • confidence 0.00
correction
Completed See added jobs *1000*
needs-review • confidence 0.00
Evidence Thread
Stephanie Kendziorski
processor • Mar 24, 2026, 12:27 PM
Submitted PA 2618745
Stephanie Kendziorski
processor • Mar 25, 2026, 11:37 AM
@Brian P @Jeannette B Wasn't sure which one of you was going to be overseeing this one.
Job 1 - approved 5.0 - let me know on this one if the time will be ok. FR has all the notes and pictures for it and only approved the 5.0 hours. I may need to contact them again and explain further and/or provide a breakdown of time if you need the additional 3.0 hours.
Job 3 approved .5
Brian Parrott
dealer_or_external • Mar 25, 2026, 12:22 PM
I spoke with the tech and he said lets try the 5 hours and see where it leads.
Stephanie Kendziorski
processor • Mar 30, 2026, 12:05 PM
Submitted for payment
Stephanie Kendziorski
processor • Apr 8, 2026, 10:11 AM
Paid $1049.75 check 3136259 4/7/2026
Claim Files
Paid claim.pdf
pdf • Apr 8, 2026, 10:12 AM • 26,154 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/April 2026/Primetime/72859/Paid claim.pdf
72859F.pdf
main-pdf • Mar 28, 2026, 2:11 PM • 423,542 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/April 2026/Primetime/72859/72859F.pdf
Approval.pdf
main-pdf • Mar 25, 2026, 11:38 AM • 24,649 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/April 2026/Primetime/72859/Approval.pdf
72859.pdf
main-pdf • Mar 24, 2026, 10:29 AM • 423,149 bytes
/home/openclaw/nas/Dropbox/MYRV 12024/8- Claims Paid/April 2026/Primetime/72859/72859.pdf