iClaims logo
Internal operations platform

Claim Detail

Search result → immediate full claim view.
Home
Claim explorer / evidence thread
Claim 13316
GRE 8220 • Alix • Approved / Unpaid • grand-design
Next Recommended Action

Await OEM Response

Overdue / escalation ready
Reason
OEM Response Deadline Exceeded
Deadline
Overdue / escalation ready
Estimated recovery
$500.00
risk 0.70 deadline Overdue / escalation ready images 39 matched 5 gaps 1

Warranty deadline timeline

Track where the claim sits in the recovery workflow, how many days have elapsed, and whether the auto-approval window or payment deadline is already in play.
Uploaded
Completed stage
132d elapsed • 0d remaining
Analyzed
Completed stage
132d elapsed • 0d remaining
Awaiting OEM
Completed stage
132d elapsed • 0d remaining
Auto-Approved
Overdue / escalation ready
132d elapsed • 0d remaining • Overdue
Payment Due
Upcoming statutory deadline
132d elapsed • 0d remaining
Escalation Eligible
Upcoming statutory deadline
132d elapsed • 0d remaining
Resolved
Upcoming statutory deadline
132d elapsed • 0d remaining

AI Claim Analysis

Estimated Recovery Amount
$500.00
What this claim may still be worth based on current evidence.
Compliance Score
30/100
Higher is cleaner. Lower means more missing support, more friction, or more OEM pushback.
Violations Detected
1
OEM Response Deadline Exceeded
Missing Items
1
missing_unit_id_photo • damage_signal_without_damage_photo
Deadline Status
Overdue / escalation ready
132 days open in the visible workflow.
Recommended Action
Await OEM Response
This is the fastest next move from the current workflow stage.

US dispute readiness

Evidence packet check

Condensed packet watch
Operational preflight for US warranty escalation: packet size, chronology, cross-references, witness checks, source grounding, and backup evidence.
Estimated pack size
26
Proxy count from docs, images, comments, and claim lines. Actual PDF pages still need final preflight.
Evidence packet lane
Condensed packet watch
Close to a bulky packet. Trim, paginate, and preflight before escalation.
Chronology
Ready to order
Visible span: Apr 23, 2026, 3:33 PM to Jun 20, 2026, 2:56 AM.
Indexed evidence
8 docs / 24 images
Use only the strongest evidence in the escalation packet; keep the rest as support material.
Cross-reference base
Available
Line items, comments, or gap flags can be tied back to supporting material.
Witness verification
Human verification required
Any statement or affidavit output must be checked by the witness before use.
AI / citation gate
Manual check required
Escalation material must keep facts, inferences, citations, and source documents separated.
Expert evidence pressure
Not signalled
No expert-evidence trigger is visible from the current image rollup.
Escalation posture
Escalation watch
132 days open in the visible workflow; risk score 0.70.

Claim Summary

Evidence summary
images=39; damage=0; unit=0; parts=0; doc=39; gaps=missing_unit_id_photo,damage_signal_without_damage_photo • Unit 2024 Grand Design • VIN 573FR3126R3348424
Path
/home/openclaw/nas/Dropbox/GRE 8220/5-Pre-Authorizations Approved- GRE/Grand Design/13316/13316 - LEVERRANCE UPDATED.pdf
Timeline
First seen Apr 23, 2026, 3:33 PM • last seen Jun 20, 2026, 2:56 AM
Evidence flags
missing unit id photo • damage signal without damage photo

Comment Intelligence

Thread depth
13 indexed side comments on this claim.
Latest visible thread signal
Aug 31, 2026, 8:08 AM • processor • No invoices in GD for these repairs as of right now.
Role mix
Dealer 0 • OEM 0 • Processor 9
Decision cues
Denial signals 0 • info / missing-doc asks 12 • approval signals 7
Best move
Work missing-doc or reply asks first from the thread.

Quick Actions

Back to search results
Run the same search again.
Open focused evidence thread
Jump straight into Dropbox side comments, notes, and support documents.
Open claim explorer
Return to the main recovery queue view.
Open evidence room
See the quick-rule cards first, then open the legal basis only if needed.

Claim Lines

customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
gap • confidence 0.73
complaint
PREFORM ROOF INSPECTION AND ADVISE IF I PD GOODW REPAIR IS NEEDED.
matched • confidence 0.91
cause
1001 CUSTOMER REQUESTED Roof inspection
matched • confidence 0.91
correction
This is another unit where the manufacturer couldn't hit he pre-drilld holes. Two of the roof vents are cracked around the screw holes The alpha sealant around the vents did not seal properly allowing water to seep in to the screw holes and now it will need 3 sheets of decking and two new roof vents
matched • confidence 0.98
complaint
CASE # 1010162 - ROOF REPLACEMENT W 1020 GRAND
matched • confidence 0.98
cause
REFER TO RI LINE FOR NOTES
partial-match • confidence 0.71
correction
REQUESTING: 46.50 HRS
partial-match • confidence 0.71
customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
matched • confidence 0.98
customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
unreviewed • confidence 0.00
customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
unreviewed • confidence 0.00
customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
unreviewed • confidence 0.00
customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
unreviewed • confidence 0.00
customer-comments
Do to manufacturer not hitting the holes that were already predrilled in the roof vent plastic it cracked the vent for the roof and not using a promoter for the alfa sal that did not stick to the vent water was able to seep past the alfa seal and get under the vent and rot the wood on the roof have seen this on multiple units
unreviewed • confidence 0.00

Evidence Thread

Alix Mongiat
processor • Apr 17, 2026, 3:09 PM
Michelle Antinoja I will need the vents separated on to a different line. They will send it back if I put it all on one. So I need to know the time you need for those separated from the roof.
Michelle Antinoja
dealer_or_external • Apr 17, 2026, 3:58 PM
@Alix M I will upload updated wo, should I also have the case number in the vent line or will that not matter?
Michelle Antinoja
dealer_or_external • Apr 17, 2026, 4:57 PM
@Alix M UPDATED WORK ORDER ADDED.
Alix Mongiat
processor • Apr 20, 2026, 6:40 AM
PA 943274 has been submitted for approval. @Michelle A They are most likely going to come back and ask me to separate the roof replacement and the decking lines so if you could tell me how much time for each of those that would be great. Thanks!
Alix Mongiat
processor • Apr 22, 2026, 10:57 AM
@Michelle A @Kaitlyn R @Matt F This has been approved for 28 hours total. I know we normally fight on roof jobs, let me know how you want me to respond to this approval or if you accept it. I also noticed I accidentally type 2 sheets of decking and it is 3 sheets. I am emailing Tony to update that right now and see if I can get a more accurate time, usually they only add 1 hour per sheet of decking though.
Matt Ferkey
dealer_or_external • Apr 23, 2026, 2:04 PM
@Alix M I am requesting reconsideration of the labor authorization on this roof replacement claim. Grand Design’s flat rate for roof replacement is 1.0 hour per lineal foot, plus 1.0 hour per sheet of roof decking replaced. This unit measures 30'11", which places the roof replacement portion at approximately 31.0 hours. In addition, this repair requires replacement of 3 sheets of roof decking, which adds another 3.0 hours. Based on Grand Design’s own flat-rate structure, this claim appears to support at least 34.0 hours. The current authorization of 28.0 hours is below Grand Design’s own flat-rate calculation for the repair. For additional comparison, the applicable RVDA flat rate for this same repair would calculate at 1.5 hours per lineal foot and 1.5 hours per sheet of decking, which would place the job at 51.0 hours. Our requested 46.5 hours is already below that benchmark. Under Wis. Stat. § 218.164(2), time allowances for warranty labor must be reasonable for the work to be performed. Given Grand Design’s own published formula, the decking required on this unit, and the broader flat-rate comparison, the current 28.0-hour authorization does not appear reasonable for the scope of this repair. Please review and revise the labor authorization accordingly.
Alix Mongiat
processor • Apr 23, 2026, 2:38 PM
I have sent this on to Grand Design. Tony Gary is assigned to this one and he NEVER responds to me, hopefully this gets a response. I did add a couple other people that work in the warranty department in hopes that will get it moving.
Alix Mongiat
processor • Apr 23, 2026, 2:56 PM
@Matt F From James Hite: The roof on this unit is only 28 feet long. We do have a chart that we work off that gives us lengths that we are allowed to approve. For the decking, you will need to additional FRC 540004 and request the decking on that line. You will need to send photos of the membrane removed from the unit showing the damaged areas. The dealerships management has read and agreed to the GDRV Policy and Procedure Manual which does reference our flat rate codes. We do know that there are sometimes circumstances, but they need to be revealed in the PA write ups when they happen. ** I will add a line for decking once they move it back to Pending status
Matt Ferkey
dealer_or_external • Apr 23, 2026, 3:44 PM
@Alix M Thank you for the clarification on your roof-length chart and on requesting the decking separately under FRC 540004. That said, the central issue remains whether the total labor allowance is reasonable for the work to be performed, as required by Wis. Stat. § 218.164(2). Grand Design’s internal flat-rate chart and policy manual do not, by themselves, resolve that question. A dealer performing a complete roof replacement in the field does not do so under the same conditions as a manufacturer or dedicated factory team with fixed scaffolding, staging, material access, and a controlled repair environment. Those differences matter when evaluating what is reasonable. For comparison, the RVDA flat rate, which is the most neutral industry benchmark available and the basis many dealers use when quoting this repair retail, allows substantially more time for a complete roof replacement than Grand Design’s current authorization. That is because it more accurately reflects the real-world labor conditions under which dealers perform this work. So while we will provide the requested membrane-off photos and can request the decking separately under FRC 540004, we do not agree that Grand Design’s current allowance resolves the broader question of reasonableness under Wisconsin law. Please review the labor allowance again in that context.
Alix Mongiat
processor • Apr 23, 2026, 3:58 PM
Sent to Grand Design. I will keep you posted.
Alix Mongiat
processor • Apr 24, 2026, 9:51 AM
I have now added the line for decking on the PA. I will let you know once we get the approval on what they are approving labor wise.
Alix Mongiat
processor • Apr 24, 2026, 10:46 AM
@Matt F @Michelle A This has now been approved for 31 hours for the roof and vents 3 hours for the decking Let me know if you accept these 34 hours total.
Alix Mongiat
processor • Aug 31, 2026, 8:08 AM
No invoices in GD for these repairs as of right now.

Claim Files

13316 - LEVERRANCE UPDATED.pdf
updated-packet • Apr 17, 2026, 4:57 PM • 74,645 bytes
/home/openclaw/nas/Dropbox/GRE 8220/5-Pre-Authorizations Approved- GRE/Grand Design/13316/13316 - LEVERRANCE UPDATED.pdf
13316 - LEVERRANCE UPDATED.pdf
updated-packet • Apr 17, 2026, 4:57 PM • 74,645 bytes
/home/openclaw/nas/Dropbox/#recycle/GRE 8220/2-Pre-Authorizations Pending- iCS/Grand Design/13316/13316 - LEVERRANCE UPDATED.pdf
13316 - LEVERRANCE UPDATED.pdf
updated-packet • Apr 17, 2026, 4:57 PM • 74,645 bytes
/home/openclaw/nas/Dropbox/GRE 8220/2-Pre-Authorizations Pending- iCS/Grand Design/13316/13316 - LEVERRANCE UPDATED.pdf
13316 - LEVERRANCE UPDATED.pdf
updated-packet • Apr 17, 2026, 4:57 PM • 74,645 bytes
/home/openclaw/nas/Dropbox/#recycle/GRE 8220/1-Pre-Authorizations Needed- iCS/Grand Design/13316/13316 - LEVERRANCE UPDATED.pdf
13316.pdf
main-pdf • Apr 17, 2026, 2:16 PM • 74,356 bytes
/home/openclaw/nas/Dropbox/GRE 8220/5-Pre-Authorizations Approved- GRE/Grand Design/13316/13316.pdf
13316.pdf
main-pdf • Apr 17, 2026, 2:16 PM • 74,356 bytes
/home/openclaw/nas/Dropbox/#recycle/GRE 8220/2-Pre-Authorizations Pending- iCS/Grand Design/13316/13316.pdf
13316.pdf
main-pdf • Apr 17, 2026, 2:16 PM • 74,356 bytes
/home/openclaw/nas/Dropbox/GRE 8220/2-Pre-Authorizations Pending- iCS/Grand Design/13316/13316.pdf
LEVERANCE - 13316.pdf
pdf • Apr 17, 2026, 2:16 PM • 74,356 bytes
/home/openclaw/nas/Dropbox/#recycle/GRE 8220/1-Pre-Authorizations Needed- iCS/Grand Design/13316/LEVERANCE - 13316.pdf